An Evaluation Of The Efficacy Of The Locked Plate With Bone Grafting İn Sanders Type Iıı And Iv İntra-Articular Calcaneus Fractures

dc.contributor.authorVarol, Ali
dc.contributor.authorÖç, Yunus
dc.contributor.authorKılınç, Bekir Eray
dc.date.accessioned2021-09-09T13:09:31Z
dc.date.available2021-09-09T13:09:31Z
dc.date.issued2021
dc.departmentİstanbul Beykent Üniversitesien_US
dc.description.abstractObjective: To demonstrate the efficacy of locking plate osteosynthesis performed by an L-shaped lateral approach in patients with Sanders type III and IV intra-articular calcaneal fractures with posterior facet displacement. Methods: Fifty-three patients with Sanders type III or IV unilateral calcaneal fractures treated with locking plates and additional bone grafting were included in the study. Böhler and Gissane angles, and heel height values were measured on the radiological examinations. Clinical results of the patients were evaluated using the American Orthopaedic Foot and Ankle Society and Maryland evaluation criteria. The presence of arthrosis was investigated with Broden's view. Preoperative and postoperative values were evaluated. Results: The mean Gissane angle was 119.32°, the mean Böhler angle was 9.47° and the mean heel height was 40.82 mm on radiographs at initial presentation of the patients. The mean Gissane angle was 114.63°, the mean Böhler angle was 23.33° and the mean heel height was 47.84 mm on the early postoperative radiographs of the patients. In patients, a mean 4.69° recovery was achieved in the Gissane angle, 13.86° in Böhler angle and 7.02 mm in heel height. On the most recent follow-up, Böhler angle was 21.49°, Gissane was 114.88° and the mean heel height was 46.95 mm. The mean American Orthopaedic Foot and Ankle Society score and Maryland score were 86.91 and 86.53, respectively, on the last follow-up. Conclusion: Internal fixation and grephonage using low-profile locking plates provides good functional results to patients since it facilitates anatomic restoration of the subtalar joint and correction of calcaneal height, width and varus/valgus heel. Keywords: Allograft; Sanders type III; Sanders type IV; bone graft; calcaneus fracture; heel height; subtalar arthrosis.en_US
dc.identifier.citationSAGE Open Medicine Volume 9: 1–8en_US
dc.identifier.doi10.1177/20503121211040954
dc.identifier.issn0031-5990
dc.identifier.pmid34434558en_US
dc.identifier.scopus2-s2.0-85113724620en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://doi.org/10.1177/20503121211040954
dc.identifier.wosWOS:000693713100001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherSAGE Publicationsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.subjectAllograften_US
dc.subjectSanders type IIIen_US
dc.subjectSanders type IVen_US
dc.subjectBone graften_US
dc.subjectCcalcaneus fractureen_US
dc.subjectHeel heighten_US
dc.subjectSubtalar arthrosisen_US
dc.titleAn Evaluation Of The Efficacy Of The Locked Plate With Bone Grafting İn Sanders Type Iıı And Iv İntra-Articular Calcaneus Fracturesen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
72 Antidiabetic, anticholinergic and antioxidant activities of aerial parts of.pdf
Boyut:
847.13 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: