Hot box measurements of pumice aggregate concrete hollow block walls
dc.contributor.author | Kus, Hulya | |
dc.contributor.author | Ozkan, Ertan | |
dc.contributor.author | Gocer, Ozgar | |
dc.contributor.author | Edis, Ecem | |
dc.date.accessioned | 2024-03-13T10:30:59Z | |
dc.date.available | 2024-03-13T10:30:59Z | |
dc.date.issued | 2013 | |
dc.department | İstanbul Beykent Üniversitesi | en_US |
dc.description.abstract | Due to its relatively low thermal conductivity characteristics and being a local product, pumice aggregate concrete (PAC) blocks are increasingly used as a masonry wall unit in Turkey. However, there is limited technical and scientific knowledge on hygrothermal performance of PAC blocks. A research project is conducted to study hygrothermal performance of PAC block walls using a calibrated hot box method. Temperature and humidity measurements were carried out at the surfaces of the test wall and in the hollows of blocks on different courses. The results, in general, indicate that the hollows of blocks perform better in terms of thermal transmittance than the lightweight solid parts of them. Noticeable changes are observed in hygrothermal behaviour of the lower and the upper courses depending on the indoor and outdoor climate test conditions. The heterogeneous material and rough surface characteristics of the blocks, in addition to the wet construction type of block wall are the most problematic issues that make measurements and assessments difficult. (C) 2012 Elsevier Ltd. All rights reserved. | en_US |
dc.description.sponsorship | TUBITAK (The Scientific and Technical Research Council of Turkey) [TUBITAK 107M532] | en_US |
dc.description.sponsorship | This work has been carried out within the research project TUBITAK 107M532, Hygrothermal performance of external walls made of pumice aggregate concrete blocks: energy and economic efficiency through life cycle funded by TUBITAK (The Scientific and Technical Research Council of Turkey). | en_US |
dc.identifier.doi | 10.1016/j.conbuildmat.2012.09.053 | |
dc.identifier.endpage | 845 | en_US |
dc.identifier.issn | 0950-0618 | |
dc.identifier.issn | 1879-0526 | |
dc.identifier.scopus | 2-s2.0-84867899944 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 837 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.conbuildmat.2012.09.053 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12662/3637 | |
dc.identifier.volume | 38 | en_US |
dc.identifier.wos | WOS:000313767900093 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Sci Ltd | en_US |
dc.relation.ispartof | Construction And Building Materials | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Hygrothermal performance | en_US |
dc.subject | Hot box | en_US |
dc.subject | Measurement | en_US |
dc.subject | Pumice | en_US |
dc.subject | Concrete block | en_US |
dc.title | Hot box measurements of pumice aggregate concrete hollow block walls | en_US |
dc.type | Article | en_US |