Hot box measurements of pumice aggregate concrete hollow block walls

Küçük Resim Yok

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier Sci Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Due to its relatively low thermal conductivity characteristics and being a local product, pumice aggregate concrete (PAC) blocks are increasingly used as a masonry wall unit in Turkey. However, there is limited technical and scientific knowledge on hygrothermal performance of PAC blocks. A research project is conducted to study hygrothermal performance of PAC block walls using a calibrated hot box method. Temperature and humidity measurements were carried out at the surfaces of the test wall and in the hollows of blocks on different courses. The results, in general, indicate that the hollows of blocks perform better in terms of thermal transmittance than the lightweight solid parts of them. Noticeable changes are observed in hygrothermal behaviour of the lower and the upper courses depending on the indoor and outdoor climate test conditions. The heterogeneous material and rough surface characteristics of the blocks, in addition to the wet construction type of block wall are the most problematic issues that make measurements and assessments difficult. (C) 2012 Elsevier Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

Hygrothermal performance, Hot box, Measurement, Pumice, Concrete block

Kaynak

Construction And Building Materials

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

38

Sayı

Künye