Three-Dimensional Evaluation of Autogenous Ramus Block Graft Donor Site and Its Relation to Mandibular Canal

dc.contributor.authorAtaman-Duruel, Emel Tugba
dc.contributor.authorErduran, Nazan Ece
dc.contributor.authorDuruel, Onurcem
dc.contributor.authorCicciu, Marco
dc.contributor.authorTozum, Tolga Fikret
dc.date.accessioned2024-03-13T10:33:06Z
dc.date.available2024-03-13T10:33:06Z
dc.date.issued2023
dc.departmentİstanbul Beykent Üniversitesien_US
dc.description.abstractSufficient bone volume is necessary for placing a dental implant in an ideal position. To restore severely insufficient bone volume, autogenous block graft procedures with various intraoral donor sites are presented in the literature. The aims of this retrospective study are to present the dimensions and volume of the potential ramus block graft site, and to evaluate possible effect of mandibular canal diameter and its position in relation to mandibular ramus block graft volume. Two-hundred cone-beam computed tomography (CBCT) images were evaluated. The maximum length, width, height, and volume of the potential ramus block graft site, mandibular canal diameter, mandibular canal-mandibular basis distance, and mandibular canal-crest distance were measured. Mandibular canal diameter, mandibular canal-crest distance, and mandibular canal-mandibular basis distance were 3.139 & PLUSMN; 0.446 mm, 15.376 & PLUSMN; 2.562, and 7.834 & PLUSMN; 1.285 mm, respectively. In addition, the dimensions of the potential ramus block graft sites were measured 11.156 & PLUSMN; 2.297 mm x 10.390 & PLUSMN; 3.420 mm x 8.816 & PLUSMN; 1.720 mm (height x length x width). Moreover, the potential ramus bone block volume was calculated as 1.076 & PLUSMN; 0.398 cm3. While a positive correlation was detected between mandibular canal-crest distance and the potential ramus block graft volume (r = .160, P = .025), a negative correlation was found between mandibular canal-mandibular basis distance and the potential ramus block graft volume (r =-.020, P = .001). Mandibular ramus is one of the predictable intraoral donor sites for bone augmentation procedures. However, ramus has some volumetric limitations related to its neighboring anatomic structures. It seems to be important to evaluate lower jaw in a 3-dimensional manner to prevent surgical complications.en_US
dc.identifier.doi10.1563/aaid-joi-D-21-00218
dc.identifier.endpage237en_US
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.issue3en_US
dc.identifier.pmid36796080en_US
dc.identifier.scopus2-s2.0-85163902584
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage233en_US
dc.identifier.urihttps://doi.org/10.1563/aaid-joi-D-21-00218
dc.identifier.urihttps://hdl.handle.net/20.500.12662/3762
dc.identifier.volume49en_US
dc.identifier.wosWOS:001018722200002
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherAllen Press Incen_US
dc.relation.ispartofJournal Of Oral Implantologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectaugmentationen_US
dc.subjectdental implanten_US
dc.subjectimagingen_US
dc.subjecttomographyen_US
dc.subjectvolumeen_US
dc.titleThree-Dimensional Evaluation of Autogenous Ramus Block Graft Donor Site and Its Relation to Mandibular Canalen_US
dc.typeArticleen_US

Dosyalar