Experimental Tests on Heat Transfer in Coil Condensers Designed for Built-in Refrigerators

dc.authoridhttps://orcid.org/0000-0002-4603-9061
dc.authoridhttps://orcid.org/0000-0002-4022-9585
dc.authoridhttps://orcid.org/0000-0003-2492-8690
dc.contributor.authorTezcan, Alper
dc.contributor.authorCihan, Ahmet
dc.contributor.authorKahveci, Kamil
dc.date.accessioned2024-03-19T08:30:35Z
dc.date.available2024-03-19T08:30:35Z
dc.date.issued2022
dc.departmentFakülteler, Mühendislik-Mimarlık Fakültesi, Makine Mühendisliği Bölümü
dc.description.abstractA vapor compression refrigeration cycle is a closed cycle consisting of a compressor, a condenser, an expansion valve and an evaporator. The performance of the cooling system is significantly dependent on the condenser. The aim of this study is to conduct heat transfer tests on the compact con-densers of built-in refrigerators and to propose improve-ment suggestions according to the test results. In the intro-duction section, information is given about the type of con-denser used in built-in refrigerators and the parameters af-fecting the heat transfer. In the material and methods sec-tion, the selected coil type condenser and the constraints on the component where it is mounted are explained. Ex-planatory information about the experimental setup to be used can also be found in this section. In the results section, the results of the experiments on the coil condenser are given. The test results in the discussion section were exam-ined and suggestions were made to increase the perfor-mance of the condenser on the refrigerator. The results show that the heat transfer capacity, which is an important parameter determining the condenser performance, and the pulldown temperature are directly related to the con-denser surface. It can also be concluded that even if the condenser thermal capacity is sufficient, the pulldown tem-perature should also be taken into account. Although the thermal capacity of the coil condenser meets the require-ments, it is observed that the pulldown temperature is not at the desired values.
dc.identifier.doi10.20854/bujse.989788
dc.identifier.endpage10
dc.identifier.issn1307-3818
dc.identifier.issue1
dc.identifier.startpage1
dc.identifier.urihttps://hdl.handle.net/20.500.12662/4535
dc.identifier.volume15
dc.institutionauthorCihan, Ahmet
dc.institutionauthoridhttps://orcid.org/0000-0002-4022-9585
dc.language.isoen
dc.publisherBeykent Üniversitesi
dc.relation.ispartofBeykent Üniversitesi Fen ve Mühendislik Bilimleri Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCoil Condenser
dc.subjectCooling System
dc.subjectHeat Transfer
dc.subjectOptimization
dc.subjectR134a
dc.subjectRefrigerators
dc.titleExperimental Tests on Heat Transfer in Coil Condensers Designed for Built-in Refrigerators
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10.20854-bujse.989788-1952328.pdf
Boyut:
1005.32 KB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: