Impact of Adverse Weather Conditions on Outage Statistics of 154 kV Power Transmission System

dc.contributor.authorOzdemir, Aydogan
dc.contributor.authorBagriyanik, M.
dc.contributor.authorKaypmaz, A.
dc.contributor.authorGul, O.
dc.contributor.authorIlisu, I.
dc.date.accessioned2024-03-13T10:30:32Z
dc.date.available2024-03-13T10:30:32Z
dc.date.issued2015
dc.departmentİstanbul Beykent Üniversitesien_US
dc.descriptionInternational conference on electronics, communications and computers -- FEB 25-27, 2015 -- Puebla, MEXICOen_US
dc.description.abstractFailures in a large electric power system comprising several transmission hardware and substation equipment are inevitable. It is clear that the number of annual failures depends on the system topology itself as well as on the environmental conditions. One of the primary reasons of major transmission line outages are severe weather conditions. The stress created by severe weather is much higher than in normal weather and increases with the severity level of the weather, leading to increases in line outage rates. Thrace part of Turkish National Power System is more important from the point of service reliability as being the most industrialized region of the country. This paper is devoted to the quantitative effects of severe weather on the outage statistics of 154 kV Turkish National Power Transmission system of the region. Moreover, a weather dependent failure rate model was proposed for that part of the system.en_US
dc.description.sponsorshipIEEE and IEEE Puebla Sec,Technical Program Comm,Dept Computing Electro Mechatronics at UDLAP,Univ Americas Puebla UDLAPen_US
dc.identifier.doi10.1109/CONIELECOMP.2015.7086954
dc.identifier.endpage34en_US
dc.identifier.isbn978-1-4799-7436-8
dc.identifier.issn2474-9036
dc.identifier.issn2474-9044
dc.identifier.scopus2-s2.0-84929235949
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage29en_US
dc.identifier.urihttps://doi.org/10.1109/CONIELECOMP.2015.7086954
dc.identifier.urihttps://hdl.handle.net/20.500.12662/3415
dc.identifier.wosWOS:000380444100032
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartof25th International Conference On Electronics, Communications And Computers (Conielecomp 2015)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleImpact of Adverse Weather Conditions on Outage Statistics of 154 kV Power Transmission Systemen_US
dc.typeConference Objecten_US

Dosyalar