| dc.description.abstract | This study evaluated the reliability and validity of the DrGoniometer smartphone application for measuring elbow flexion compared to the Universal Goniometer (UG). Fifty-six healthy participants were assessed by two physiotherapists, with anatomical landmarks marked by an independent examiner. Intra- and inter-rater reliability were calculated using intraclass correlation coefficients (ICC), and measurement error was assessed via the standard error of measurement (SEM) and Bland - Altman analysis. DrGoniometer showed excellent intra-rater reliability (ICC = 0.99; SEM = 0.69 degrees) and higher inter-rater reliability (ICC = 0.87; SEM = 1.28 degrees) than UG (ICC = 0.54; SEM = 3.87 degrees). Cronbach's alpha values were also higher for DrG (0.929) than UG (0.704). Although Bland - Altman plots indicated no systematic bias, they revealed wide limits of agreement, suggesting limited interchangeability between tools. These findings support the DrGoniometer as a reliable tool for elbow flexion assessment, especially in contexts requiring high intra-rater consistency and digital precision. | |
| dc.identifier.doi | 10.1080/1091367X.2025.2538249 | |
| dc.identifier.endpage | 94 | |
| dc.identifier.issn | 1091-367X | |
| dc.identifier.issn | 1532-7841 | |
| dc.identifier.issue | 1 | |
| dc.identifier.scopus | 2-s2.0-105011746457 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 87 | |
| dc.identifier.uri | https://doi.org./10.1080/1091367X.2025.2538249 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12662/10690 | |
| dc.identifier.volume | 30 | |
| dc.identifier.wos | WOS:001533765300001 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Routledge Journals, Taylor & Francis Ltd | |
| dc.relation.ispartof | Measurement in Physical Education And Exercise Science | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260128 | |
| dc.subject | Elbow flexion | |
| dc.subject | smartphone-based goniometry | |
| dc.subject | reliability | |
| dc.subject | validity | |
| dc.title | The Reliability and Validity of DrGoniometer, a Smartphone Application for Measuring Elbow Flexion | |
| dc.type | Article |