Measurements With Silicon Photomultipliers Of Dose-Rate Effects İn The Radiation Damage Of Plastic Scintillator Tiles İn The Cms Hadron Endcap Calorimeter

dc.authorid249433en_US
dc.contributor.authorBilki, Burak
dc.contributor.author., ve diğer.
dc.date.accessioned2020-10-13T12:46:59Z
dc.date.available2020-10-13T12:46:59Z
dc.date.issued2020
dc.departmentİstanbul Beykent Üniversitesien_US
dc.description.abstractMeasurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb(-1) . The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using Co-60 sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.en_US
dc.identifier.citationJournal Of Instrumentatıon, 15/(6), 2020en_US
dc.identifier.doi10.1088/1748-0221/15/06/P06009
dc.identifier.issn1932-6203
dc.identifier.scopus2-s2.0-85088533574
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org/10.1088/1748-0221/15/06/P06009
dc.identifier.wosWOS:000545350900009en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherThe CMS Collaborationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.subjectLarge detector systems for particle and astroparticle physicsen_US
dc.subjectScintillators, scintillation and light emission processes (solid, gas and liquid scintillators)en_US
dc.titleMeasurements With Silicon Photomultipliers Of Dose-Rate Effects İn The Radiation Damage Of Plastic Scintillator Tiles İn The Cms Hadron Endcap Calorimeteren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
30 Measurements With Silicon Photomultipliers Of Dose-Rate Effects İn The Radiation Damage Of Plastic Scintillator Tiles İn The Cms Hadron Endcap Calorimeter.pdf
Boyut:
1.39 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: