Calorimetric Measurements with Extremely Fine Spatial Resolution

Küçük Resim Yok

Tarih

2016

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. With its extremely fine segmentation of the readout based on 1 x 1 cm(2) pads, the DHCAL provides unprecedented details of both electromagnetic and hadronic showers. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

Açıklama

IEEE Nuclear Science Symposium / Medical Imaging Conference / Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD) -- OCT 29-NOV 06, 2016 -- Strasbourg, FRANCE