Secondary Emission Calorimetry

dc.contributor.authorBilki B.
dc.contributor.authorDilsiz K.
dc.contributor.authorOgul H.
dc.contributor.authorOnel Y.
dc.contributor.authorSouthwick D.
dc.contributor.authorTiras E.
dc.contributor.authorWetzel J.
dc.date.accessioned2024-03-13T10:00:54Z
dc.date.available2024-03-13T10:00:54Z
dc.date.issued2022
dc.departmentİstanbul Beykent Üniversitesien_US
dc.description2022 IEEE Nuclear Science Symposium, Medical Imaging Conference, and Room Temperature Semiconductor Detector Conference, IEEE NSS MIC RTSD 2022 -- 5 November 2022 through 12 November 2022 -- -- 196914en_US
dc.description.abstractIn high-radiation environments, electromagnetic calorimetry is particularly challenging. To address this, a feasible approach involves constructing a sampling calorimeter that employs radiation-hard active media, albeit at the expense of high energy resolution. In response, we developed an innovative technique, secondary emission calorimetry, which offers radiation resistance, rapid response, robustness, and cost-effectiveness. Our efforts involve the creation of prototype secondary emission sensors, subjected to comprehensive testing within test beams. In the secondary emission detector module, incident charged hadrons or electromagnetic shower particles trigger the generation of secondary emission electrons from a cathode. These generated electrons are subsequently amplified in a manner similar to the process within photomultiplier tubes. This report provides an insight into the principles underlying secondary emission calorimetry, presents findings from beam tests, and outlines Monte Carlo simulations that project towards the potential application of large-scale secondary emission electromagnetic calorimeters. © 2022 IEEE.en_US
dc.description.sponsorshipACKNOWLEDGMENT B. Bilki acknowledges support under 118C224.en_US
dc.identifier.doi10.1109/NSS/MIC44845.2022.10399023
dc.identifier.isbn9781665488723
dc.identifier.scopus2-s2.0-85185380150en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.urihttps://doi.org/10.1109/NSS/MIC44845.2022.10399023
dc.identifier.urihttps://hdl.handle.net/20.500.12662/2851
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartof2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conferenceen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleSecondary Emission Calorimetryen_US
dc.typeConference Objecten_US

Dosyalar